Flow attenuation downstream of the weir can be done with flat and bucket types of stilling basin. If the planned
weir is more than 10 meters high and the river transports rock material, then the rock layer is strong enough to
choose a bucket type stilling basin. One of the effectiveness of energy dissipation is determined by the value of the
hydraulic jump length (Lj). In the bucket type still basin, the radius (R) greatly affects the length of the hydraulic
jump. In planning the bucket type stilling basin according to the USBR standard, the Froude number (Fr) value is
calculated first, from the USBR graph the minimum radius of the bucket (Rmin) can be calculated so that the water
level downstream of the bucket (Tmin and TMax) is obtained. The Rmin graph developed by USBR is strongly
influenced by the analytically calculated downstream speed without validation. The purpose of this study is to
obtain the bucket radius (R) according to the downstream velocity value which is validated from the physical
model test so that the jump length correction factor is obtained which is influenced by the bucket radius, then this
value can be used as a reference in determining the length or area of the security area. downstream of the river so
as not to be eroded by water when a flood occurs. Physical model test was carried out with flume length 4.1 m,
flume width 0.15 m and flume height 0.24 m. Furthermore, 3 variations of the radius of the stilling basin were
made, namely R1 = 6 cm, R2 = 7 cm and R3 = 8 cm and then flowed water with 27 experimental variations. Then
the water level above the weir crest was measured (Hd), when jumping (y1), after jumping (y2) and the length of
the hydraulic jump (Lj). After analyzing the relationship between variables, it was found that the water height
when jumping (y1) and Froude number (Fr) are factors that affect the hydraulic length (Lj) in bucket type stilling
basin. By modifying the Silvester equation (σ = 3.0 and = 1.17) the hydraulic jump length is close to the observed
results with the relative error rate E = 25.8%, NSE = 0.9, MAE = 6.0 and RMSE = 3.1.
Keywords: stilling basin, bucket type, hydraulic jump, froude number
[error in script]
Item Type: | Peer Review |
---|---|
Subjects: | 600 Technology and Applied Science > 620 Engineering > 624 Civil Engineering |
Divisions: | Faculty of Engineering > Department of Civil Engineering (S1) |
Depositing User: | Nanang Saiful Rizal | nanangsaifulrizal@unmuhjember.ac.id |
Date Deposited: | 31 Dec 2022 02:17 |
Last Modified: | 31 Dec 2022 02:17 |
URI: | http://repository.unmuhjember.ac.id/id/eprint/15768 |