STUDI KETEPATAN METODE ANALISA STATIK EKIVALEN TERHADAP ANALISIS STRUKTUR METODE NILAI D PADA STRUKTUR SISTEM RANGKA PEMIKUL MOMEN DENGAN PENINJAUAN BEBAN GEMPA MENGGUNAKAN RESPONS SPEKTRA DESAIN SESUAI SNI 1726-2012



AZIZ, ABDUL (2025) STUDI KETEPATAN METODE ANALISA STATIK EKIVALEN TERHADAP ANALISIS STRUKTUR METODE NILAI D PADA STRUKTUR SISTEM RANGKA PEMIKUL MOMEN DENGAN PENINJAUAN BEBAN GEMPA MENGGUNAKAN RESPONS SPEKTRA DESAIN SESUAI SNI 1726-2012. Undergraduate thesis, UNIVERSITAS MUHAMMADIYAH JEMBER.

[thumbnail of a. PENDAHULUAN.pdf] Text
a. PENDAHULUAN.pdf

Download (3MB)
[thumbnail of b. ABSTRACK.pdf] Text
b. ABSTRACK.pdf

Download (258kB)
[thumbnail of c. BAB I.pdf] Text
c. BAB I.pdf

Download (267kB)
[thumbnail of d. BAB II.pdf] Text
d. BAB II.pdf
Restricted to Repository staff only

Download (1MB) | Request a copy
[thumbnail of e. BAB III.pdf] Text
e. BAB III.pdf
Restricted to Repository staff only

Download (318kB) | Request a copy
[thumbnail of f. BAB IV.pdf] Text
f. BAB IV.pdf
Restricted to Repository staff only

Download (605kB) | Request a copy
[thumbnail of g. BAB V.pdf] Text
g. BAB V.pdf
Restricted to Repository staff only

Download (255kB) | Request a copy
[thumbnail of h. DAFTAR PUSTAKA.pdf] Text
h. DAFTAR PUSTAKA.pdf

Download (259kB)
[thumbnail of i. LAMPIRAN.pdf] Text
i. LAMPIRAN.pdf
Restricted to Repository staff only

Download (2MB) | Request a copy

Abstract

Building development in Indonesia, including in Banyuwangi Regency, requires structural planning that ensures earthquake resistance. The equivalent static analysis method is widely used due to its simplicity, particularly for low-rise buildings. However, regulatory changes from PPTIUG 1981 to SNI 1726:2012 have reclassified some structures—previously considered regular—into irregular categories. This shift necessitates a reassessment of the accuracy of using the equivalent static method. This study aims to evaluate the accuracy of the D-Value method on the 3-story hospital building of Al-Huda, focusing on three key parameters: inter-story drift, natural period, and structural stability (P-Δ effect). Calculations were conducted based on existing project data, structural analysis methods, and the requirements outlined in SNI 1726:2012. The analysis results indicate that the structure satisfies the criteria for a Type D structure. The values of inter-story drift, period, and stability remain within acceptable limits according to seismic design standards. Therefore, the use of the D-Value method within the framework of equivalent static analysis is still considered appropriate for this building.

Contribution
Nama Dosen Pembimbing
NIDN/NIDK
Dosen Pembimbing
PRIYONO, PUJO
NIDN0022126402
Dosen Pembimbing
DEWI, ILANKA CAHYA
NIDN0721058604

Item Type: Thesis (Undergraduate)
Keywords/Kata Kunci: D-Value method, Building Structure, Earthquake
Subjects: 600 Technology and Applied Science > 690 Planning, Anaysis, Engineering Design
Divisions: Faculty of Engineering > Department of Civil Engineering (S1)